Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum

Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum

Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum  is an outdoor distribution equipment with rated voltage of 12kV and three-phase  alternating current of 50Hz.It is mainly used to open and close load current, overload current and short circuit current in power system.It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and dirty environment.

Product Description

ZW32 series outdoor high voltage vacuum circuit breaker  is an outdoor distribution equipment with rated voltage of 12kV and three-phase  alternating current of 50Hz.It is mainly used to open and close load current, overload current and short circuit current in power system.It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and dirty environment.

Basic Info.

 

Model NO. ZW32-12 Arc-extinguishing Medium Vacuum
Installation Fixed Structure Recloser
Poles Number 3 Type Circuit Breaker
Function Vacuum Circuit Breaker Certification ISO9001-2000, CE, CCC
Rated Voltage 12kv Rated Frequency ISO9001-2000, CE, CCC
Mechanical Life 10000 Times Rated Current 630A
Transport Package Export Standard Wooden Case Trademark CHNGS
Origin China HS Code 8537209000
Production Capacity 500 Pieces/Week

Product Parameters

Ltem Describition Unit Data
1 Rated Voltage KV 12
2 Rated Frequency HZ 50
3 Rated Current A 630
4 Rated Short Circuit Breaking Current KA 20
5 Rated peak withstand current (peak) KA 50
6 Rated short-time withstand current KA 20
7 Rated short-time withstand current KA 50
8 Mechanical life Times 1000
9 Rated short circuit breaks number Times 30
10 Power frequency withstand voltage (1min) (wet)(dry)phase to phase/isolating distance KV 42/48
11 Lighting impulse withstand voltage (peak) (wet)(dry)phase to phase/isolating distance KV 75/85
12 Power frequency withstand voltage ofsecondary circuit
( min)
KV 2

Detailed Photos